CPC-8401
19'4U Height Compact PCI Chassis
Features:
·Tally with PICMG criterion, 19" rack-mounted
or table 4U CompactPCI industrial computer/server system
platform ·Support 8 block horizontal installed
6U¡Á160MM front insert card and 8 block 60¡Á80MM back
insert card,the two cards must support mechanical configuration
criterion tally with backboard signal definition and PICMG
criterion ·Full module configuration design,convenience
system installation and maintenance
Support one super-thin harddisk and CD-ROM ·Full
EMC electromagnetism compatible design to meet high reliability
working requestion of system ·Two 175W pedundance
AC server powers (can customize 175W redundance DC server
powers) ·Industry server special low-noise
direct current no-brushing long life cooling fan,convenient
for ventilation ·Tally with CPCI Packet Switching
Backplane Specification PICMG 2.16 R1.0 (September 5,
2001) criterion ·Tally with CPCI Computer Telephony
Specification PICMG 2.5 R1.0 ·Tally with CPCI
Specification PICMG 2.0 R3.0 (October 1, 1999) ·Tally
with CPC I Hot Swap Specification PICMG 2.1 R1.0 (August
3, 1998) ·Tally with CPCI System Management
Specification PICMG 2.9 R1.0 (February 2, 2000) ·Tally
with Keying of CPCI Boards and Backplanes PICMG 2.10 R1.0
(October 1, 1999) ·Tally with CPCI Power Interface
Specification PICMG 2.11 R1.0 (October1, 1999) ·Dimension£º177£¨height£©¡Á310£¨depth£©¡Á482£¨width£©mm
Specifications:
Backplane • block backboard mechanical configuration full
tally with PICMG technolegy criterion,bus configuration
fully self-definition • Physics Dimension: 6U£¨262MM£©X8
slot£¨167MM£©-thickness 4.4MM£¬10 layer PCB configuration • Impedance features: 65ohm 10%(commonly signal)£¬120ohm
10%(differece signal) • Power supply: ATX power
socket,connect power backboard via power change thread
Power module: • Industry server special power • Output
power:º175W ¡££«5V/25A£»£«3£®3V/25A£»£«12V/3A£»£12V/1A • Input power£º90 ¡«264VAC£»36 ¡«72VDC£¬18¡«
36VDC can matched • Power:º0.99 •
MTBF º100000hrs • Protection of out-power£¬out-current
and out-heat • Efficiency:Ý73% •
Wave:50mv or 1%£¬random output • Safety:CUL
EN 60950/UL 1950£»EMI;EN55022 Class A • FCC
Class A radiated andConducted,EMS;IEC 1000-4 •
Working temperature:º0~70oC with derating above 40oC and
15CFM forced air (100%:40oC,50%:70oC) • Relative humidity: <95%@40oC
Monitor module£º • 8 bit micro processor and 12 bit A/D switch, monitoring
8 channel power,9 temperature sensor ,6 fans •
The state of working power,warming,reposition direct,adjust
rotate speed of fan according temperature •
Support WIN95/98/NT
|